Insulation R-Value Calculator - Heat loss through a wall from R-value and ΔT. Enter R-value (imperial, e.g. R-13), Temperature difference (°), Area (m²) to get an instant result.
Formel
Enter the imperial R-value printed on the insulation (e.g. R-13, R-30). R-value(SI) = imperial R-value × 0.1761 m²·K/W. Heat flux = ΔT / R-value(SI). Total heat loss (W) = flux × area.
Trin for trin
- Enter the R-value (imperial, e.g. R-13).
- Enter the Temperature difference (°).
- Enter the Area (m²).
- Click Calculate to see your result instantly.
Eksempel fra virkeligheden
Example: With R-value (imperial, e.g. R-13) = 13, Temperature difference (°) = 20, Area (m²) = 50, the Insulation R-Value Calculator gives Flux W M2: 8.7358, Total Heat Loss W: 436.7895, R Value Si M2kw: 2.2894.
Ofte Stillede Spørgsmål
What does a higher R-value mean?
What is ΔT?
Why enter the R-value printed on the insulation (e.g. R-13, R-30)?
What inputs does the Insulation R-Value Calculator need?
How accurate is the Insulation R-Value Calculator?
Is the Insulation R-Value Calculator free to use?
Om Isolerings-R-værdiberegner
R-value measures a material's resistance to heat flow. Higher R-values indicate better insulating ability. Building codes specify minimum R-values for walls, attics, floors, and crawl spaces depending on climate zone. The Insulation R-Value Calculator on CalculatorCast helps you determine the total R-value of a wall or ceiling assembly from the individual materials and their thicknesses.
R-values of different materials are additive in a layered assembly. The total R-value equals the sum of the R-values of all layers, including structural materials, air gaps, insulation, sheathing, and cladding. For example, a typical 2x4 wall with R-13 batt insulation, 1/2-inch drywall (R-0.45), and 1/2-inch OSB sheathing (R-0.63) has a total effective R-value of approximately 14.08 for the cavity section.
Common insulation R-values per inch: fiberglass batt insulation is R-3.1 to R-3.8 per inch, cellulose blown-in is R-3.5 to R-3.8 per inch, spray foam (open cell) is R-3.6 per inch, spray foam (closed cell) is R-6.0 to R-7.0 per inch, and rigid foam board (EPS) is R-4 per inch. Our calculator includes a reference table of common material R-values per inch.
Climate zone requirements in the United States range from R-13 wall insulation in warm Zone 1 to R-21 or higher in cold Zone 7. Attic insulation requirements range from R-30 to R-60 depending on climate. Our calculator helps you check whether a proposed assembly meets these requirements or helps you choose the right combination of materials to achieve a target R-value.