CalculatorCast

kVA-laskuri

Muunna jännite ja virta kVA-arvoksi yksi- tai kolmivaihejärjestelmille.

Johdanto

kVA Calculator - Convert voltage and current to kVA for single-phase or three-phase systems. Enter Voltage (V), Current (A), Phase to get an instant result.

Kaava

Single-phase: kVA = (V × I) / 1000. Three-phase: kVA = (√3 × V_line × I_line) / 1000.

Vaihe vaiheelta

  1. Enter the Voltage (V).
  2. Enter the Current (A).
  3. Enter the Phase.
  4. Click Calculate to see your result instantly.

Käytännön esimerkki

Example: With Voltage (V) = 120, Current (A) = 10, Phase = no, the kVA Calculator gives Kva: 1.2, Three Phase: no.

Usein Kysytyt Kysymykset

Is kVA the same as kW?
Only when power factor is 1. In general, kW (real power) = kVA (apparent power) × power factor, so kVA is always equal to or greater than kW.
Why are generators and transformers rated in kVA?
Because their current-carrying and heat-dissipation limits depend on current and voltage directly, independent of the connected load's power factor - kVA captures that limit regardless of what's plugged in.
What inputs does the kVA Calculator need?
You'll need to provide: Voltage (V), Current (A), Phase. All fields use sensible defaults, so you can see a working example immediately and then adjust the values to match your own numbers.
How accurate is the kVA Calculator?
The kVA Calculator gives an estimate. Formula used: Single-phase: kVA = (V × I) / 1000. Three-phase: kVA = (√3 × V_line × I_line) / 1000. Actual outcomes vary with factors the formula does not capture, so treat the result as a guide, not a guarantee. Entering realistic, correct values gives the most useful result.
Is the kVA Calculator free to use?
Yes, the kVA Calculator is completely free, requires no signup, and runs instantly in your browser.

Tietoa: kVA-laskuri

kVA (kilovolt-amperes) is the standard unit of apparent power used to rate transformers, generators, UPS systems, and large electrical equipment. Understanding kVA and how it relates to kilowatts (kW) is essential for properly sizing these systems. The kVA Calculator converts between kW and kVA, calculates kVA from voltage and current, and handles both single-phase and three-phase systems. For single-phase systems: kVA equals voltage times current divided by 1,000. A single-phase transformer supplying 240V at 20 amps provides 4,800 VA or 4.8 kVA. For three-phase systems: kVA equals the square root of 3 times line voltage times line current divided by 1,000. The square root of 3 factor (approximately 1.732) accounts for the three-phase relationship. A 480V three-phase motor drawing 30 amps per phase consumes 1.732 times 480 times 30 divided by 1,000, which equals approximately 24.9 kVA. The kW to kVA conversion requires the power factor: kVA equals kW divided by power factor. If a load consumes 8 kW with a power factor of 0.80, it draws 8 divided by 0.80 equals 10 kVA from the supply. This is why undersized transformers can overheat even when the watt consumption appears acceptable: the transformer must supply the full kVA. For transformer sizing, add up the kVA demands of all loads, multiply by a demand factor (not all loads run simultaneously), then apply a safety margin of 10 to 25 percent, and select the next standard transformer size. Standard transformer sizes: 15, 25, 37.5, 50, 75, 100, 150, 167, 200, 225, 250, 300, 333, 500, 750, 1000 kVA. This calculator helps you determine the appropriate transformer size for any load configuration.