Lumikuormalaskuri
Mitoittava lumikuorma yksinkertaistetulla ASCE 7 -menetelmällä.
Lyhennystaulukko
| # | Maksuerä | Pääoma | Korko | Jäljellä oleva saldo |
|---|---|---|---|---|
Kasvu ajan myötä
| Vuosi | Sijoitettu | Arvo |
|---|---|---|
Johdanto
Snow Load Calculator - Design snow load using simplified ASCE 7 method. Enter Ground snow load (kPa), Exposure factor, Thermal factor, Importance factor to get an instant result.
Kaava
Simplified ASCE 7 flat-roof snow load: design snow load = 0.7 × exposure factor × thermal factor × importance factor × ground snow load. This mirrors the ASCE 7 flat-roof snow load equation, pf = 0.7 × Ce × Ct × Is × pg, without the additional code-required slope and thermal adjustments.
Vaihe vaiheelta
- Enter the Ground snow load (kPa).
- Enter the Exposure factor.
- Enter the Thermal factor.
- Enter the Importance factor.
- Click Calculate to see your result instantly.
Käytännön esimerkki
Example: With Ground snow load (kPa) = 1.5, Exposure factor = 1, Thermal factor = 1, Importance factor = 1, the Snow Load Calculator gives Design Snow Load: 1.05.
Usein Kysytyt Kysymykset
Is this the full ASCE 7 snow load calculation?
Where do I find my ground snow load (pg)?
Can I use this for a building permit?
What inputs does the Snow Load Calculator need?
How accurate is the Snow Load Calculator?
Is the Snow Load Calculator free to use?
Tietoa: Lumikuormalaskuri
Snow accumulation on roofs creates significant structural loads that must be considered in building design in cold climates. The Snow Load Calculator on CalculatorCast computes the design roof snow load from the ground snow load and roof-specific parameters using the methods of ASCE 7 (the standard US loading code).
The design flat roof snow load is Pf equals 0.7 times Ce times Ct times Is times Pg, where Pg is the ground snow load in psf (from local maps in the building code), Ce is the exposure factor (0.7 for exposed roofs, 1.0 for partially exposed, 1.2 for sheltered), Ct is the thermal factor (1.0 for heated buildings, 1.1 for unheated), and Is is the importance factor (1.0 for ordinary occupancy, 1.1 for essential facilities).
Ground snow loads in the United States range from less than 10 psf in the southern states to over 100 psf in the mountains of the Pacific Northwest and Rocky Mountains. Local building departments specify the ground snow load applicable in each location.
For sloped roofs, the flat roof snow load is reduced by the slope factor Cs, which decreases from 1.0 at slopes below 15 degrees to 0 at slopes of 70 degrees or more. Snow slides or falls off steep roofs before it accumulates to the same depth as on a flat roof.
Unbalanced snow loads on sloped roofs, drift loads at higher-to-lower-roof transitions, and sliding snow loads at eaves are additional load cases required in ASCE 7 that our calculator addresses in its extended mode.
The Snow Load Calculator is free on CalculatorCast and works on all devices without registration.