3상 전력 계산기
선간전압과 전류로 3상 전기 시스템의 전력을 계산합니다.
상환 일정표
| # | 월 상환액 | 원금 | 이자 | 잔액 |
|---|---|---|---|---|
시간에 따른 성장
| 연도 | 투자 금액 | 값 |
|---|---|---|
소개
Three Phase Power Calculator - Calculate power for a three-phase electrical system from line voltage and current. Enter Line voltage (V), Line current (A), Power factor to get an instant result.
공식
Three-phase real power: P = √3 × V_line × I_line × PF, where V_line is line-to-line voltage and PF is power factor (assumed 1 if not entered).
단계별 안내
- Enter the Line voltage (V).
- Enter the Line current (A).
- Enter the Power factor.
- Click Calculate to see your result instantly.
실제 예시
Example: With Line voltage (V) = 480, Line current (A) = 50, Power factor = 1, the Three Phase Power Calculator gives Watts: 41569.2194, Power Factor Used: 1.
자주 묻는 질문
What voltage should I enter - line-to-line or line-to-neutral?
Why is three-phase power preferred for larger loads?
What inputs does the Three Phase Power Calculator need?
How accurate is the Three Phase Power Calculator?
Is the Three Phase Power Calculator free to use?
3상 전력 계산기 소개
Three-phase electrical power is the standard distribution method for commercial, industrial, and large residential electrical systems. Unlike single-phase power that uses one alternating current waveform, three-phase uses three waveforms offset by 120 degrees, providing more efficient power delivery, smoother motor operation, and reduced conductor requirements for the same power level. The Three Phase Power Calculator helps you compute power, current, and voltage relationships in three-phase systems. Three-phase power can be calculated in two ways depending on what information is available. When line voltage (voltage between any two of the three phases) and line current are known: apparent power in VA equals the square root of 3 (approximately 1.732) multiplied by line voltage multiplied by line current. Real power in watts equals the square root of 3 times line voltage times line current times power factor. The square root of 3 factor accounts for the 120-degree phase relationship. When phase voltage (voltage from phase to neutral) and phase current are known: apparent power equals 3 times phase voltage times phase current. This directly sums the power from all three phases. For a balanced 480-volt, 3-phase system with 30 amps per phase and power factor of 0.85: apparent power equals 1.732 times 480 times 30, which equals 24,941 VA or approximately 24.9 kVA. Real power equals 24.9 kVA times 0.85, which equals approximately 21.2 kW. Three-phase systems are specified by their line voltage. Common industrial voltages in North America are 208V (from 120/208V 3-phase 4-wire systems common in light commercial), 240V (3-phase 3-wire delta), 480V (3-phase 4-wire wye, standard for industrial motors), and 600V (used in some industrial applications). In Europe, 400V (230/400V 3-phase 4-wire) is the standard. Understanding three-phase power is essential for sizing transformers, selecting motor starters and drives, calculating conductor ampacity, and sizing generator and UPS systems.