Apparent Power Calculator - Calculate apparent power (VA) from voltage and current, single or 3-phase. Enter Voltage (V), Current (A), Phase to get an instant result.
Wzór
Single-phase: S = V × I. Three-phase: S = √3 × V_line × I_line. Result is in volt-amps (VA).
Krok po kroku
- Enter the Voltage (V).
- Enter the Current (A).
- Enter the Phase.
- Click Calculate to see your result instantly.
Przykład z życia
Example: With Voltage (V) = 120, Current (A) = 10, Phase = no, the Apparent Power Calculator gives Apparent Power Va: 1200, Three Phase: no.
Często Zadawane Pytania
How is apparent power different from real power?
Why is apparent power used to size equipment like transformers?
What inputs does the Apparent Power Calculator need?
How accurate is the Apparent Power Calculator?
Is the Apparent Power Calculator free to use?
O Kalkulator Mocy Pozornej
Apparent power is the total power supplied to an AC circuit, measured in volt-amps (VA) or kilovolt-amps (kVA). Unlike real power (watts), which measures only the energy doing useful work, apparent power represents the total current and voltage the electrical supply must provide, including the reactive component that oscillates between the source and inductive or capacitive loads. The Apparent Power Calculator helps you compute this value and understand its role in sizing electrical equipment. Apparent power is calculated as the product of RMS voltage and RMS current: apparent power in VA equals voltage times current. For a 240-volt circuit drawing 15 amps, apparent power is 3,600 VA or 3.6 kVA, regardless of the nature of the load. The relationship between apparent power, real power, and reactive power forms the power triangle. Apparent power (VA) is the hypotenuse; real power (W) is the horizontal leg; reactive power (VAR) is the vertical leg. The power factor is the cosine of the angle between apparent and real power: power factor equals real power divided by apparent power. Apparent power determines the required capacity of electrical equipment. Transformers, generators, UPS systems, and inverters are rated in kVA because they must supply both the real and reactive components of load current, regardless of the load's power factor. A 5 kVA transformer can supply 5,000 VA to the load; the real power (kW) it delivers depends on the load's power factor. For power supplies, UPS systems, and inverters, the kVA rating represents the maximum apparent power the unit can handle. A UPS rated at 1000 VA with 0.8 power factor can supply 800 watts of real power. When sizing UPS or generator capacity, always use kVA based on the actual loads to be connected. This calculator performs all apparent power conversions and shows the power triangle for any combination of real power, reactive power, and power factor.