Introduction
Power Factor Calculator - Calculate power factor from real and apparent power, or from phase angle. Enter Real power (W), Apparent power (VA) to get an instant result.
Formule
PF = Real Power (W) ÷ Apparent Power (VA). If a phase angle (φ) between voltage and current is known instead, PF = cos(φ).
Étape par étape
- Enter the Real power (W).
- Enter the Apparent power (VA).
- Click Calculate to see your result instantly.
Exemple concret
Example: With Real power (W) = 900, Apparent power (VA) = 1000, the Power Factor Calculator gives Power Factor: 0.9.
Questions Fréquentes
What does a power factor less than 1 mean?
Can power factor be negative or greater than 1?
What inputs does the Power Factor Calculator need?
How accurate is the Power Factor Calculator?
Is the Power Factor Calculator free to use?
À propos de Calculateur de Facteur de Puissance
Power factor is a measure of how efficiently electrical power is being used in an AC circuit, expressed as a ratio between real power (doing useful work) and apparent power (the total power drawn from the supply). A power factor of 1.0 (unity) means all the power drawn is being used productively. Lower power factors indicate wasted capacity in the electrical system. The Power Factor Calculator helps you compute and understand power factor for any AC load. Power factor is defined as the cosine of the phase angle between voltage and current waveforms in an AC circuit. In a purely resistive circuit (like incandescent light bulbs or electric heaters), voltage and current are in phase (phase angle zero), giving a power factor of 1.0. In inductive loads (motors, transformers, fluorescent lighting), current lags behind voltage. In capacitive loads, current leads voltage. The mathematical relationship: real power (W) equals apparent power (VA) times power factor. Rearranging: power factor equals real power divided by apparent power. A motor drawing 10 kVA from the supply but performing only 8 kW of actual work has a power factor of 0.80. Reactive power (VAR, volt-ampere reactive) is the component of apparent power that does no useful work but must still be supplied and returned by the generator and transmission lines. Reactive power equals apparent power times the sine of the phase angle. In the motor example: reactive power equals 10,000 times sin(arccos(0.80)) equals 10,000 times 0.60 equals 6,000 VAR. Low power factor has real costs in utility-scale and industrial settings. Utilities often impose power factor penalties on large commercial and industrial customers with power factors below 0.90 or 0.95. Improving power factor through capacitor banks reduces apparent power demand, potentially lowering utility bills and reducing stress on electrical infrastructure. This calculator converts between power factor, phase angle, and the three power quantities: real (W), reactive (VAR), and apparent (VA).