Consulte a ampacidade nominal de um fio de cobre THHN de acordo com sua bitola (Tabela 310.16 do NEC).

Introdução

Wire Ampacity Calculator - Look up the rated ampacity of a copper THHN wire gauge (NEC Table 310.16). Enter Wire gauge to get an instant result.

Fórmula

Looks up the rated ampacity of a given copper AWG/kcmil wire size from NEC Table 310.16, 75°C column (THHN/THWN-2 insulation).

Passo a passo

  1. Enter the Wire gauge.
  2. Click Calculate to see your result instantly.

Exemplo do mundo real

Example: With Wire gauge = 12, the Wire Ampacity Calculator gives Ampacity Amps: 25, Basis: NEC Table 310.16, copper THHN 75°C (differs for aluminum/other insulation ratings).

Perguntas Frequentes

Is this ampacity the same for aluminum wire?
No - aluminum conductors have lower ampacity than copper at the same gauge; this table is copper-only. Aluminum requires a separate NEC Table 310.16 column and is typically upsized versus an equivalent copper circuit.
Does insulation type change the ampacity?
Yes - the 75°C column applies to common insulations like THHN/THWN-2 and XHHW; lower-temperature-rated insulation (like older TW at 60°C) has a lower ampacity for the same conductor size.
What inputs does the Wire Ampacity Calculator need?
You'll need to provide: Wire gauge. All fields use sensible defaults, so you can see a working example immediately and then adjust the values to match your own numbers.
How accurate is the Wire Ampacity Calculator?
The Wire Ampacity Calculator gives an estimate. Formula used: Looks up the rated ampacity of a given copper AWG/kcmil wire size from NEC Table 310.16, 75°C column (THHN/THWN-2 insulation). Actual outcomes vary with factors the formula does not capture, so treat the result as a guide, not a guarantee. Entering realistic, correct values gives the most useful result.
Is the Wire Ampacity Calculator free to use?
Yes, the Wire Ampacity Calculator is completely free, requires no signup, and runs instantly in your browser.

Sobre a Calculadora de Ampacidade de Fio

Wire ampacity is the maximum current a wire can carry continuously without exceeding its temperature rating or creating a fire hazard. It is determined by the wire gauge (AWG), conductor material, insulation type, and installation conditions. The Wire Ampacity Calculator provides NEC-compliant ampacity values for any wire configuration, ensuring safe electrical installations. The NEC ampacity tables (Table 310.12 and 310.16) specify current ratings for copper and aluminum conductors based on insulation temperature rating. The most commonly used residential and commercial wire uses 60 degrees Celsius, 75 degrees Celsius, or 90 degrees Celsius rated insulation. Higher temperature ratings allow higher ampacity for the same gauge, but most terminals and devices are rated for 75 degrees Celsius, which limits the usable ampacity to the 75-degree column regardless of wire rating. Standard ampacity for copper wire at 75 degrees Celsius: 14 AWG is 20 amps, 12 AWG is 25 amps, 10 AWG is 35 amps, 8 AWG is 50 amps, 6 AWG is 65 amps, 4 AWG is 85 amps, 2 AWG is 115 amps, 1 AWG is 130 amps, 1/0 AWG is 150 amps, 2/0 AWG is 175 amps, 3/0 AWG is 200 amps, and 4/0 AWG is 230 amps. Derating factors apply when multiple wires are bundled together or when ambient temperature exceeds 30 degrees Celsius. Bundled wires share heat and each wire's ampacity must be derated. With 4 to 6 current-carrying conductors in a conduit, each wire's ampacity is derated to 80 percent of the table value. With 7 to 9 conductors, derate to 70 percent. Aluminum wire is a common choice for large service entrance conductors and feeders. Aluminum ampacity is lower than copper: 4 AWG aluminum has the same 85-amp ampacity as 6 AWG copper.